OUR STANDARD RANGE OF CREMATORS TO COMPLY WITH THE NEW VERSION 2.1 ‘ANIMAL BY PRODUCTS’ GUIDANCE PRODUCED BY DEFRA

 

Our great asset as a company is our continuous experience in the human and animal cremation industry since 1972 (the company was formed 90 years ago). Not only do we manufacture new thermal units but we also undertake renewals and repairs of all makes and models in the industry. Therefore we can see the advantage and disadvantages of the whole range of Uk models and advise on the unit best suited to your needs. We can also provide help regarding general DEFRA, planning & licensing compliance.

Undertaking our essential works at our premises and delivering a turnkey unit for connection to services on site by local suppliers can minimize our costs. We can happily undertake these site works at extra cost. We never leave clients without support and back up and we will supervise and provide reasonable training at no extra cost. (All costs are plus vat)

The degree of sophistication and controls tend to increase up the unit range. We are happy to provide solutions in liaison to customer requirements and provide the extra cost of increased sophistication on a particular unit. Our aim is to provide excellent value products in a method that allows the client to have clear identifiable costs with a choice of fuel use.

 We have full specifications for the units listed overleaf and we would be happy to receive your requirements or your own design requirements. The information listed below is a summary of our standard model range. The smallest takes only small domestic type animals and the largest will take horses & cows. Further information is available on request.

 

ALL COSTS ARE EX WORKS & EXCLUDE INSTALLATION, TRANSPORT, FUEL & ELECTRICITYSUPPLY, VAT ETC (VALID FROM JANUARY 2005)

 

AS A GUIDE TO FUEL CONSUMPTIONS, UNITS WORK AT FULL POWER FOR PREHEAT TIMES AND THEN

OPERATE AT HALF POWER FOR CREMATIONS (DEPENDENT ON CALORIFIC VALUE OF CREMATIONS)

 

ONE CUBIC METER NATURAL GAS @ 25 PENCE PER CUBIC METER WILL PROVIDE APPROXIMATELY 10.7kW,

THIS CONVERTS TO 2.33 PENCE PER KILOWATT

 

ONE LITRE DIESEL @ 35 PENCE PER LITRE WILL PROVIDE APPROXIMATELY 12kW, THIS CONVERTS

TO 2.92 PENCE PER KILOWATT

 

ONE LITRE LPG @ 40 PENCE PER LITRE WILL PROVIDE APPROXIMATELY 7kW, THIS CONVERTS TO

5.71 PENCE PER KILOWATT

 

MODEL:   AD-ENVIRONS 8Kg / HOUR       DEFRA APPROVED           BASIC COST:£7,700

VOLUMES & AREAS    

EXTERNAL

1.0 w x 2.456 h x 0.83 l   VERTICAL CYLINDER (SEE ABOVE)

 

CASING INTERNAL

1.23m3 (1500KG)

 

HEARTH & DOOR OPENING

0.261m2 & 0.45 x 0.3m

RESIDENCE TIME  /  CAPACITY / PREHEAT TIME        

2.07 seconds / 8Kg/Hr / 21mins

HEAT INPUT

BURNERS

2 off G3B (35Kw @ 0.5gph) burners. Continuous run fan switch on primary 

 

BURNERS EXTRA COST

Gas burners at an extra cost of £730-00 in total 

AIR INPUT

TERTIARY FAN

Included (15SF – 0.37kW)

 

VENTURI FAN

Excluded from basic cost

CONTROL PANEL

UNIT MOUNTED, ISOLATOR, 2 off CAL 3300 WITH 1 SET POINT FOR EACH BURNER, PRIMARY OFF SWITCH

STACK

DIAMETERS & HEIGHT

2m x 250/450mm insulated flue section included in cost

 

 

MODEL:    AD-ENURE 14Kg / HOUR           DEFRA APPROVED            BASIC COST:£8,600

VOLUMES & AREAS

EXTERNAL

1.25 w x 1.25 h x 2.776 l   HORIZONTAL CYLINDER (SEE BELOW)                                                                                                               

 

CASING INTERNAL

2.44m3 (2000KG)

 

HEARTH & DOOR OPENING

1.265m2 & 0.7m diameter (COLD HEARTH)

RESIDENCE TIME / CAPACITY / PREHEAT TIME

2.37 seconds /  14Kg/Hr / 30 mins

HEAT INPUT

BURNERS

2 off G5 (58Kw @ 1gph) burners. Continuous run fan switch on burners 

 

BURNERS EXTRA COST

Gas burners at an extra cost of £730-00 in total 

AIR INPUT

TERTIARY FAN

Included (15F – 0.37kW)

 

VENTURI FAN

Excluded from basic cost

CONTROL PANEL

 UNIT MOUNTED, ISOLATOR, 2 off CAL 3300 WITH 1 SET POINT FOR EACH BURNER, DOOR LIMIT SWITCH,

2 OFF MECHANICAL TIMERS, FANS & BURNER SWITCHES

STACK

DIAMETERS & HEIGHT

3m x 360/560mm insulated flue section included in cost                    

 

 

MODEL:   AD-ENCASE 20Kg / HOUR                                            BASIC COST:£9,800

VOLUMES & AREAS    

EXTERNAL

1.25 w x 1.25 h x 3.934 l   HORIZONTAL CYLINDER (SEE BELOW)                                                                 

 

CASING INTERNAL

4.5m3 (2500KG)

 

HEARTH & DOOR OPENING

2.32m2 &  0.844 m diameter (COLD HEARTH)

RESIDENCE TIME / CAPACITY / PREHEAT TIME        

2.40 seconds / 20Kg/Hr / 30 mins

HEAT INPUT

BURNERS

1 x G5 (58 kW @ 1gph) & 1 x G10 (78kW @ 1.5gph) burner. Continuous run fan switch on burners

 

EXTRA COSTS

Gas burners at an extra cost of £730-00 in total. Cost of a top loading door in addition to the normal front swing away door £870-00 

AIR INPUT

TERTIARY FAN

Included  (15F – 0.55kW)

 

VENTURI FAN

Excluded from basic cost

CONTROL PANEL

UNIT MOUNTED, ISOLATOR, 2 OFF CAL 3300 WITH 1 SET POINT FOR EACH BURNER, DOOR LIMIT SWITCH,

2 OFF MECHANICAL TIMERS, FANS & BURNER SWITCHES

STACK

DIAMETERS & HEIGHT

3m x 400/600mm insulated flue section included in cost

 

 

MODEL:   AD-ENCORE 20Kg / HOUR        DEFRA APPROVED          BASIC COST:£14,750

VOLUMES & AREAS    

EXTERNAL

1.33 w x 1.83 h x 2.016 l   RECTANGULAR BOX (HOT HEARTH) (SEE BELOW)

 

CASING INTERNAL

3.8m3 (5000KG)

 

HEARTH & DOOR OPENING

0.92m2 & 0.82 x0.475m (HOT HEARTH)

RESIDENCE TIME / CAPACITY / PREHEAT TIME        

2.42 seconds / 20Kg/Hr / 41 mins

HEAT INPUT

BURNERS

1 x G5 (44 kW @ 0.5gph) & 1 x G20 (180kW @ 3gph) burner. Continuous run fan switch on primary 

 

BURNERS EXTRA COST

Gas burners at an extra cost of £730-00 in total 

AIR INPUT

TERTIARY FAN

Included  (15F – 0.55kW)

 

VENTURI FAN

Included (QP4010 – 1.5kW)

CONTROL PANEL

UNIT MOUNTED, ISOLATOR, 2 OFF CAL 3300 WITH 1 SET POINT FOR EACH BURNER, DOOR LIMIT SWITCH,

2 OFF MECHANICAL TIMERS, FANS & BURNER SWITCHES

STACK

DIAMETERS & HEIGHT

3m x 400/600mm insulated flue section included in cost

 

 

  MODEL:  AD-ENTENTE 38Kg / HOUR         DEFRA APPROVED         BASIC COST:£19,800

VOLUMES & AREAS    

EXTERNAL

2.25 w x 1.83 h x 2.25 l   RECTANGULAR BOX (HOT HEARTH) (SEE BELOW)

 

CASING INTERNAL

8m3 (8000KG)

 

HEARTH & DOOR OPENING

2 off 0.92m2 & 2 off 0.87x0.475m (HOT HEARTH)

RESIDENCE TIME / CAPACITY / PREHEAT TIME

2.5 seconds / 38Kg/Hr / 44 mins

HEAT INPUT

BURNERS

2 off G5 (44Kw @ (0.5gph) burners & secondary RL28.1 (325kW  @ 2 x 3.5gph) burner. Continuous run fan switch on primary 

 

BURNERS EXTRA COST

Gas burners at an extra cost of £1215-00 in total 

AIR INPUT

TERTIARY FAN

Included (27F – 0.55kW)

 

VENTURI FAN

Included (QP4010 – 2.2kW)

CONTROL PANEL

TEMPERATURE CONTROLLERS

3 off (cal 3300)

(mounted on unit!)

MECHANICAL TIMERS

Included

 

SWITCHES & PANEL ISOLATOR

Included

 

DOOR LIMIT SWITCH

Included

STACK

DIAMETERS & HEIGHT

3m x 500/700mm insulated flue section included in cost

 

 

MODEL: AD-ENVIABLE 48-300Kg / HOUR     DEFRA APPROVED     BASIC COST:£27,850

THIS UNIT CAN BE FITTED WITH LIMITERS TO POTENTIALLY ALLOW USE IN THE <50Kg EXEMPT BAND & CAN BE A HOT HEARTH MODEL WITH A CENTRAL CREMATING CHAMBER (FLUES ABOVE & BELOW CREMATING CHAMBER). IT CAN ALSO BE A COLD HEARTH WITH THE CREMATING CHAMBER AT GROUND LEVEL. A COLD HEARTH REFRACTORY IS MORE STRUCTURALLY ROBUST AND FUEL EFFICIENT BUT IS PRONE TO TALLOW BUILD UP AS THE HEARTH ACTS AS A RESEVOIR FOR THE TALLOW. (HOT HEARTH VERSION PHOTO SHOWN  ABOVE )

VOLUMES & AREAS    

EXTERNAL

2.12 w x 3.10 h x 4.11 l   RECTANGULAR BOX (HOT HEARTH) (SEE ABOVE)

 

CASING INTERNAL

22.68m3 (HOT HEARTH) (14000KG)

 

HEARTH & DOOR OPENING

4.79m2 & 1.06 x 1.66 m

RESIDENCE TIME / CAPACITY / PREHEAT TIME

2.033 seconds / 48+ Kg/hr (@restricted burn rate capacity) / 44mins

HEAT INPUT

BURNERS

3  off G10 (120Kw @ 2.25gph) burners & RL130 (1005kW @ 10gph x 2) secondary burner. Continuous run fan switch on primary   

 

BURNERS EXTRA COST

Gas burners at an extra cost of £1460-00 in total 

AIR INPUT

TERTIARY FAN

Included (Q166 – 4kW)

 

VENTURI FAN

Included (QP4815 – 5.5kW

CONTROL PANEL

TEMPERATURE CONTROLLERS

2 off with 2 set points for hi-lo burner (cal 3300)

(mounted on unit!)

MECHANICAL TIMERS

Included

 

SWITCHES & PANEL ISOLATOR

Included

 

DOOR LIMIT SWITCH

Included

STACK

DIAMETERS & HEIGHT

3m x 555/755mm insulated flue section included in cost

 

FOR PET CREMATORIA THE STANDARD INDUSTRY MODEL IS THE AD-ENCORE BUT A CHEAPER ALTERNATVE IS THE AD-ENURE. THE DISADVANTAGES OF THE AD-ENURE IS THE DAILY CAPACITY IS LOWER AND IT IS A COLD HEARTH UNIT (TALLOW BUILD UP). HOWEVER THE FUEL EFFICIENCY IS MUCH BETTER THAN THE AD-ENCORE AND UNLESS THE CREMATORIUM IS GUARANTEED TO BE BUSY STRAIGHT AWAY THEN IT WOULD BE BEST TO START WITH THE AD-ENURE AND EITHER UPGRADE LATER TO THE AD-ENCORE  (PART EXCHANGE) OR JUST TO ADD A SECOND AD-ENURE TO INCREASE CAPACITY.

 

PLEASE ENQUIRE IF SECONDHAND CREMATORS ARE AVAILABLE – WE HAVE AN AD-ENCORE & AD-ENURE AT PRESENT.

 

PLANNING PERMISSION, A SITE LICENSE, A WASTE CARRIERS LICENSE AND DEFRA AUTHORISATION WILL PROBABLY BE REQUIRED.

 

BUILDING SHOULD BE ON A SMOOTH LEVEL BASE AWAY FROM RESIDENTIALOR COMMERCIAL DEVELOPMENT. A SITE WITH POTENTIAL FOR MEMORIALS & GARDENS NEAR A MAIN ROAD WOULD BE AN EXCELLENT ADVANTAGE. WORD OF MOUTH WILL BE THE BEST & PROBABLY THE ONLY ECONOMIC FORM OF ADVERTISING

 

INCOME STREAMS ARE HIGHLY DEPENDENT ON HAVING A GOOD RELATIONSHIP WITH LOCAL VETERINARY PRACTICES AND HAVING A GOOD CATCHMENT AREA. IT WILL BE UNLIKELY TO BE A FULL TIME OCCUPATION FOR A NUMBER OF YEARS. THERE IS A TRADE ASSOCIATION -   www.appcc.org.uk.  IT WOULD BE WORTHWHILE TO SEE AND DISCUSS WITH EXISTING FACILITIES.




   
   
   